  • 9 Amazing Fun Facts about solar energy you probably didn’t know

    9 Amazing Fun Facts about solar energy you probably didn’t know

    Fun Facts about solar energy

    1. The world has installed 68 GW of solar PV power plants in just 2 years(2012 & 2013), almost the same as it installed in the previous 40 years combined

    2. Many renewable energy sources such as wind, hydro and biomass are mainly derived from solar energy. Therefore, solar acts as a mother of most energy sources.

    3. By 2050, International Energy Agency(IEA) says that the solar will be world’s single largest source of electricity, supplying close to 30% of total. That’s up from 1% currently.

    4. The Super Solar Impulse 2 is a plane that flew all around the world by just solar power.

    5. Sunlight can generate electricity not just through solar panels, but also by generating steam and running a turbine through Concentrating solar power (CSP).

    6. Albert Einstein was the first scientist who got the Nobel Prize for his work on photovoltaic effect.

    7. In thin film solar panels, the semiconductor thickness is less than 5% of what it is in crystalline panels

    8. Solar and wind energy compliment each other which means when there is sun, there is usually a little wind and vice versa. That’s how solar-wind hybrid power plants make sense.

    9. The solar panels used in space gets power 24*7 as it receives sunlight all the time.

    If you know similar interesting fact, please leave it in the comment section below.

    For more information about installing solar panels for your residential or commercial purpose, contact us here: Apollo Power Systems.

  • 7 Tips for Controlling Costs in Electrical Contracting Projects

    7 Tips for Controlling Costs in Electrical Contracting Projects

    The ultimate objectives of a contractor or end-user for capital electrical projects, regardless of size or scale, are often two-fold: complete the project on schedule and under budget. Controlling expenses during the course of a project is vital to achieving both objectives since time may be thought of as being equivalent to money.

    Construction and maintenance of generating stations, substations, collecting lines, distribution lines, and transmission lines of any size can all fall within the purview of electrical contractors. Therefore it is advisable to hire an electrical contractor after considering the 7 tips given below to control the costs of your project.

    1. Make a well-structured plan with a thoroughly defined scope for every stage of the project

    The electrical contractor should be able to comprehend your project goals in terms of a detailed scope analysis. There shouldn’t be any surprises during any capital project, and the preconstruction phase is the perfect time to avoid such confusion. Making a detailed strategy significantly lowers your project risk.

    2. Track the progress at every stage of work

    One technique that is employed by many electrical contracting companies is keeping a daily job record. The record may be kept physically or via the use of computer software. A record of daily accomplishments and any adjustments made as a result of unforeseen situations might be kept in the daily employment notebook.

    3. Maintain & stick to the timeline for the timely completion of the project

    Electrical project teams frequently utilise a three-week timeline since it may be used as a conversation point for forward planning during project meetings. In order to plan out the specifics of the upcoming few weeks’ worth of work, the foreman or site supervisor sometimes uses a three-week schedule on-site, delving into more granular details than the project schedule.

    4. Consider prefabrication when necessary to save time and cost

    Prefabrication allows you to assemble the electrical material in advance at an offsite location before it’s installed at the job site. It decreases labour expenses and enables greater quality control of the assembling of electrical equipment. According to studies, prefabricated workspaces make it possible to assemble electrical components at a fraction of the expense of doing so on a construction site. Prefabrication reduces the footprint of construction on-site by requiring less space for electrical equipment installation and less manpower in the client’s facilities.

    5. Set a strong and clear communication protocol to avoid delays and miscommunication

    It’s important to establish channels of communication early on in the project.

    There are a few issues that must be resolved in advance, such as:

    • How to communicate problems effectively, whether by phone, email or within a project management platform.
    • Who should be contacted about any difficulties and how they like to be contacted
    • Which stakeholders need to be informed and how; not everyone will wish to receive a copy of every email.

    6. Utilize a skilled workforce

    With high turnover comes many problems. The electrical contractor should employ professional staff with field expertise and deep experience. Having a skilled workforce can significantly impact the outcome of the project. It can help in the reduction of accidents, time delays et

    7. Maintain on-site safety protocols

    Workplace accidents are caused by unsafe procedures. Aside from the obvious human costs associated with any injury, work-related accidents may result in workers’ compensation claims and even legal action.

    The selected contractor is required to uphold a well-established and thorough safety programme that guarantees staff are adequately trained in all aspects of safe work procedures. This reduces workplace accidents and maintains project budgets and timelines.

    Strong communication that is effectively maintained amongst all parties will establish the groundwork for a project’s success. Consider making thorough plans, monitoring the job site, and using a transparent, standardised project management methodology.

    About Apollo Electrical Contracting Services

    Apollo Power Systems is a well-known leading electrical contractor with extensive knowledge in all realms of electrical work. Their electrical contractors are known for their quality of work, arduous design systems and a strong inclination towards work ethics.

    Apollo Power Systems is one of the most reliable and robust electrical contracting agencies in South India. They provide end-to-end electrical contracting solutions which include

    Visit Apollo Power Systems to know more about end-to-end Electrical Contracting solutions or contact +91 9591073031.

  • 7 Important Steps for Diesel Generator Maintenance

    7 Important Steps for Diesel Generator Maintenance

    To generate electrical energy, a diesel generator combines a diesel engine with an electric generator (typically an alternator). This is an example of an engine-generator. A diesel compression-ignition engine often is built to run on fuel oil, but other variants are adaptable for other liquid fuels or natural gas.

    They require less maintenance due to their longevity, reliability, and sturdiness, and they are also regarded as less expensive to operate due to lower fuel costs than other forms of fuels such as gasoline and propane.

    They can resist heavy loads for long periods of time and start the power supply on full load in minutes, but they must be serviced on a regular basis to guarantee that they continue to produce excellent power throughout their service life. To ensure maximum service time for the generator and proper operation when it is called upon to supply electricity, the ideal generator maintenance practice is to follow the manufacturer’s maintenance schedule.

    The best defence against utility power outages is to have a well-designed and well-maintained standby power system. They can be life-threatening for hospitals and other health-care facilities. Outages can be extremely costly for organisations like data centres. Government offices, police agencies, fire stations, airports, and water/sewage treatment plants are among the vital facilities at risk.

    Proper diesel generator maintenance ensures that your equipment keeps running for years to come and these key points are essential. The precaution maintenance tips for the diesel generator guarantee an uninterrupted power supply that is innocuous and consistent for all the needs intended. They include the following aspects:

    1. Routine General Inspection

    The exhaust system, fuel system, DC electrical system, and engine must all be closely monitored during the operation of the diesel generator for any leakage that could result in dangerous situations. Proper maintenance, as with any internal combustion engine, is critical. Diesel Genset is no different, and the most critical maintenance is oil changes every 500 hours of operation to ensure a long and trouble-free life, but some applications may demand shorter servicing times, which is why after-sales services must be excellent. If possible, inspect every two weeks, or once a month at the very least, for better diesel generator maintenance. Regular inspections are also required for the alternator, controllers, AVR, and full sensor system, as well as wiring, harnesses for integrity.

    2. Lubrication Service

    Using a dipstick, check the engine oil while shutting down the generator at regular intervals. Allow the oil in the top areas of the engine to drain back into the crankcase, and follow the API oil classification and viscosity requirements provided by the engine manufacturer. Add the same grade and brand of oil to keep the oil level as close to the full mark on the dipstick as possible.

    Oil and filters must be replaced at predetermined intervals. Check with the engine manufacturer for instructions on how to drain the oil and replace the oil filter, as well as how to properly dispose of them to avoid environmental damage or liability.

    3. Cooling System

    During shutdown times, check the coolant level at the set interval. After allowing the engine to cool, remove the radiator cap and, if necessary, add coolant until the level is about 3/4 in. Also, keep an eye on your coolant filters and replace them as needed. A balanced coolant mixture of water, antifreeze, and coolant additives is required for heavy-duty diesel engines. Examine the radiator’s exterior for obstructions, then remove any debris or foreign material with a soft brush or cloth, being careful not to damage the fins. Radiator flushing is also an important part of diesel generator maintenance to minimize overheating and excessive engine temperatures. If low-pressure compressed air or a stream of water in the opposite direction of typical airflow are available, use them.to clean the radiator.

    4. Fuel System

    Within a year, diesel generators is susceptible to contamination and corrosion, thus regular generator set exercise is strongly recommended to burn up stored fuel before it declines. Because of the water vapour that builds and condenses in the fuel tank, the fuel filters should be drained at the appropriate intervals.

    If the gasoline is not utilised and replaced in three to six months, regular testing and fuel cleaning may be required. A routine general inspection should involve checking the coolant level, oil level, fuel system, and starting system as part of preventive maintenance. Regularly inspect the charge-air cooler piping and hoses for leaks, holes, cracks, dirt, and debris that may be blocking the fins or loose connections.

    While the engine retains its mechanical properties, it is susceptible to issues with diesel fuel quality. The chemical make-up of diesel fuel has altered in recent years; at low or high temperatures, a certain proportion of biodiesel releases contaminants, while at warm temperatures, a certain percentage of biodiesel mixed with water (condensation) might be a breeding ground for bacteria. Furthermore, reducing Sulphur diminishes lubrication, which eventually causes the fuel-injection pumps to become clogged.

    Furthermore, when acquiring a genset, it is crucial to be aware that a variety of optional accessories are available to extend maintenance intervals and guarantee that the genset continues to provide reliable power throughout its life.

    5. Testing Batteries

    Standby power system failures are frequently caused by weak or undercharged starter batteries. The battery must be kept completely charged and well-maintained to minimise diminishing, with frequent testing and inspection to determine the battery’s current status and avoid any generator start-up issues. They must also be cleaned and the battery’s specific gravity and electrolyte levels must be checked on a regular basis.

    Testing batteries: Measuring the output voltage of the batteries is insufficient to determine their ability to provide adequate starting power. Because batteries’ intrinsic resistance to current flow increases as they age, the only correct way to determine terminal voltage is under load. This suggestive test is conducted automatically on some generators each time the generator is started. Use a manual battery load tester on other generator sets to check the condition of each starting battery.

    Cleaning the batteries: Wipe them off with a moist cloth anytime dirt appears to be excessive. Remove the battery cables and wash the terminals with a solution of baking soda and water (14 pound baking soda to 1 quart water) if corrosion is present around the terminals. Make sure the solution doesn’t get into the battery cells, and after you’re done, flush the batteries with clean water. Apply a little coating of petroleum jelly to the terminals after reinstalling the connections.

    Checking the electrolyte level in open-cell lead-acid batteries: Check the electrolyte level at least every 200 hours of operation in open-cell lead-acid batteries. Fill the battery cells with distilled water to the bottom of the filler neck if they are low. When the generator is not in use, always unplug the batteries.

    6. Routine diesel generator maintenance exercise

    Regular exercise keeps engine parts lubricated and prevents oxidation of electrical contacts, uses up gasoline before it degrades, and aids in engine starting reliability. Engine exercise should be performed at least once a month for at least 30 minutes with the engine loaded to one-third of the nameplate rating.

    7. Keep your Diesel Generator Clean

    When the engine is nice and clean, oil drops and other faults are easy to identify and fix. Hoses and belts can be visually inspected to ensure that they are in good working order. Checking your equipment on a regular basis can prevent wasps and other annoyances from nesting in it. The more a generator is utilized and relied on, the more maintenance it requires. A generator set that is infrequently utilized, on the other hand, may not require as much attention.

    Other things should keep in mind –

    Clearing the air cleaner

    After 500 hours of engine running, the air cleaner should be serviced with a filter element made of special highly porous cardboard or, if necessary, by using the clogged signalize. Purging the primary filter constituent, which traps dust that enters the air cleaner, is part of servicing the air cleaner. It is necessary to cleanse the control filter element and replace it with the primary one in this instance. Make sure the fresh air input and hot air discharge windows or ducts aren’t closed or blocked as well.

    Rinsing the engine breathers

    After every 2 000 hours of engine running, the engine breathers should be cleaned with diesel fuel. Breathers on diesel generators are cleaned and purged with compressed air after removing the housings and detaching the breathers from the cylinder heads cover caps. After that, the breathers and their housings should be reinstalled.

    Apollo Power Systems has expertise in Load Study, Diesel Generators Sizing (DG Sizing), Electrical Distribution along with proficiency in Generator Paralleling (DG Paralleling) / Synchronization, Designing Room Acoustics & Treatment for Diesel Generators and Erection & Installation. Together, we offer the most optimized solutions both in terms of technical and commercial without any compromises.

    Apollo’s dedicated Service division services all types of generators up to 4000 kVA and provides a variety of Annual Maintenance Contracts (AMCs) with predetermined response times and service quality. The in-house Service department is capable of servicing practically any generator, regardless of make or model.

    Service team, which is led by industry professionals, is made up of trained, experienced, dedicated, and skilled Service Engineers, Product Support Executives, and Service Managers who work 24 hours a day, seven days a week to resolve issues with the DG sets and AMF / Synchronizing panels that they maintain.

    The Generator Service Division Offers:

    • Major and Minor overhaul of Diesel / Gas Generator Engines and Alternators
    • Annual Maintenance Contract (AMC) and/or Service Line Agreements (SLA)
    • Preventive Maintenance Programs
    • Performance Monitoring and Systematic Diagnostic and Failure Analysis
    • Diagnostic Analysis facility using special tools
    • Spares & Consumables Management for the DG sets undertaken for servicing
    • Consultation and Orientation/Training on all maintenance-related issues
  • 5 Tips for Choosing the Right Electrical Contractor for your Business

    5 Tips for Choosing the Right Electrical Contractor for your Business

    A power supply is a critical component of any business. It is the lifeblood of all operations and without it, everything will come to a standstill. Without power, there will be no computers, no lights, and no air conditioning.

    Electrical contractors are the ones who install, maintain, and repair electrical systems in a building. They are usually hired by the building owner or by the construction company to ensure that you get an up-to-code and safe electrical system at your business.

    It’s crucial to your business’s success and safety to select the right electrical contractor, whether you are remodeling the entire building or just retrofitting the lighting.

    Choosing the right electrical contractor can be a daunting task. But these 5 simple tips would help anyone to choose the right electrical contractor.

    1. Check for Experience with Commercial & Industrial Projects

    Always ensure that the electrical contractors that are going to be hired have commercial experience. Commercial and industrial projects are more complex as compared to residential ones. The project would require skilled contractors having enough experience in the industrial electrical field.

    2. Verify the License and Insurance

    When a commercial electrical contractor is hired, it is important to ensure that they have the appropriate licensing and insurance to carry out the project. A type of Electrical Contractor license is a Super Grade License, which is proof of their skills and abilities which would be required to fulfill certain norms set by federal laws to get the permit. As a company providing the service, they are obliged to provide a copy of the insurance certificate.

    The license and insurance certificate also confirms that the electrical contractors have the proper electrical training and in case of any injuries or accident, the workers are themselves liable.

    3. Check out Customer Reviews & Feedback

    Reviews are a great way to find the right contractor. Reviews can be found on social media, the company’s website, or on review websites. Reviews are a great way to learn about what other customers have experienced with the company. Reviews can also be in the form of client testimonials, text reviews, or video reviews – https://youtu.be/LhLEXRMLjyc

    These reviews can be very helpful in determining which contractor to choose for the project.

    4. Look out for recommendations & suggestions from your network

    Getting recommendations from professional colleagues, friends, and family members will help in narrowing down the list and also the names of those with who they have professionally worked before. It would be easier to trust and follow them up.

    5. Compare Quotation & Pricing based on your RFP

    It is very important to know the estimate, as it would give an idea about the budget of the project the contractors are being hired for. It would also be easy to assess the service, their experience, the time they would require, and their professionalism for the money being paid. The more information in hand, the better decisions can be made.

    Known for its vast knowledge in all aspects of electrical works, Apollo Power Systems provides end-to-end Electrical contracting services. Electrical contractors in Apollo are known for their quality work, their experience with difficult design systems, and their strong sense of ethics. Apollo Power Systems is one of the most reliable electrical work contractors in South India.

    The main electrical contracting services provided by Apollo are – Transformer Substation Construction Services (includes electrical design, development, maintenance, and testing services), Transmission and Distribution Construction services (includes electrical design, development, maintenance, and testing services), Internal Electrification and Electrical maintenance services, EHT(Extra High Tension) Work Towers – Transmission Lines, and Substation Work, HT(High Tension) Works, Transformers and Yards and Internal and LT(Low Tension) Works.

    If you are a business and thinking about whom to approach for your next project regarding the electrical contracting services, then no doubt Apollo Power systems should be on your mind!